| Model | HSJ-DALI240-12 | HSJ-DALI240-24V | HSJ-DALI240-36V | HSJ-DALI240-48V | |
| Output | DC Voltage | 6~12V | 12~24V | 24~36V | 36~48V |
| Voltage Tolerance | ±3% | ||||
| Rated current | 0~20A | 0~10A | 0~6.6A | 0~5A | |
| Rated power | 240W | 240W | 240W | 240W | |
| Input | Voltage Range | 100-265VAC | |||
| Frequency Range | 47~63HZ | ||||
| Power Factor (Typ.) | PF>=0.98/220V | ||||
| Full Load Efficiency(Typ.) | 86% | 87% | 88% | 88% | |
| AC Current(Typ.) | 0.67A/220VAC | 0.66A/220VAC | 0.65A/220VAC | 0.64A/220VAC | |
| Leakage current | <0.7mA/220VAC | ||||
| Protection | Short Circuit | Protection type: Hiccup mode, recovers automatically after fault condition is removed | |||
| Over Load | <=120% | ||||
| Over Circuit | <=1.4*Iout | ||||
| Over temperature | 100ºC±10ºC shut down o/p voltage, re-power on to recover | ||||
| Environment | Working TEMP. | -40~+60ºC | |||
| Working Humidity | 20~95%RH,non-condensing | ||||
| Storage TEM.,Humidity | -40~+80ºC,10~95%RH | ||||
| TEMP.coefficient | ±0.03%/ºC(0~50ºC) | ||||
| Vibration | 10~500Hz,5G 12min./1 cycle,period for 72min.each along X,Y,Z axes | ||||
| Safety & EMC | Safety standards | EN61347-1 EN61347-2-13 IP66 | |||
| Withstand voltage | I/P-O/P:3.75KVAC I/P-FG:1.88KVAC O/P-FG:0.5KVAC | ||||
| Isolation resistance | I/P-O/P I/P-FG O/P-FG:100MΩ/500VDC/25ºC/70%RH | ||||
| EMC EMISSION | Compliance toEN55015,EN61000-3-2 (>=50%load) | ||||
| EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6 ,11,EN61547,A light industry level (surge4KV) | ||||
| Others | Weight | 1.24Kg | |||
| Size | 260*70*40mm(L*W*H) | ||||
| packing | 320*275*175mm/12pcs/CTN | ||||
| Notes | 1. All parameters NOT specially mentioned are measured at 220VAC input , rated load and 25ºC of ambient temperature. 2.Tolerance:includes set us tolerance, line regulation and load regulation . 3.The power supply is considered as a component that will be operated in combination with final Equipment. Since EMC performance will be affected by the complete installation, the final equipment manufactures must be-qualify EMC Directive on the complete installation again. | ||||
DALI dimming main features 1) Add DALI signal to D1 and D2 lines. 2) The DALI protocol can control 16 groups of 64 addresses, and the power of a single lamp body can be individually addressed and monitored. 3) A single lamp body power supply or group programming can be realized to adjust or switch the brightness in a period of time. 4) The longest transmission data cable is 300 meters, or the voltage drop cannot exceed 2V.